Fitting Requirements
Headroom requirements
Cordula Roller and Cordula Excel require a minimum of 300mm headroom for doors up to 2500mm in opening height and 350mm headroom for door up to 3500mm opening height.
Cordula Manual requires a minimum headroom of 300mm.
Cordula Compact requires just 205mm headroom for doors with an opening height up to 2150mm.
External doors
In applications where the door is installed externally the remote control system must be installed either inside the garage or in a waterproof box (not included).
Cordula Excel restrictions
Cordula Excel is not available as supply only as it must be installed by a trained installer. Cordula Excel can not be installed externally. The door must be installed so that the entire coil is above the opening.
The low level external override option is not available for Cordula Excel. In cases where the garage door is the only means of entry to the garage a battery backup will be required.
All Cordula Excel doors are supplied with 90mm guide rails as standard.
Extreme weather conditions
High winds and high temperatures can cause increased deflection of the door. It is the installer's responsibility to ensure that the door is packed off the wall sufficiently to allow for door movement during these extreme weather conditions.